In establishing any novel component, the development process is expected to involve three stages (see Table 8.1d):
Because of the wide normal range of some plasma proteins and potential inter-batch variation of assays, it is suggested that novel units and controls be produced and assayed in parallel, with the novel technology being the only variable. A less costly alternative, if logistics permit, is to do a pooled paired comparison, where two units are pooled, and one half processed by the novel technique. This provides greater statistical power for fewer units assayed, and is particularly important for storage studies. As it may not be appropriate to compare plasmapheresis and whole blood derived plasma, data could be compared against manufacturer’s claims or published literature where there isn’t a comparable plasmapheresis process in place.
The number of units to be studied should be based on the study objectives and design and determined by statistical analysis based on the difference between test and control units to be detected. A sample size of at least 16 test or controls is suggested for the evaluation of new fresh frozen plasma/cryoprecipitate components for transfusion and this same sample size is suggested here if using an unpaired study. Fewer units (≥10) will be required if a pooled and split study design is used, however this approach will not be suitable for all studies, e.g. for studies looking at contact activation where individual donor susceptibility is important. While ABO group may not be as relevant here as when levels of FVIII and von Willebrand factor are considerations, it is recommended that validation should include an equal mix of group O and non-group O donations.
Ideally provision should be made for storing and testing paired units or aliquots from each unit at every time point, as thawing out three or four different packs at each time point introduces excessive variation. However, a pre-validation should be done to ensure that the behaviour of the aliquoted component during storage is the same as that in full sized units.
The extent of any evaluation depends in part on the degree of novelty of the method used to collect plasma. Table 8.5 gives a summary of which assays are recommended in different situations. Advice may be sought from SACBC on the validation requirements for plasma components for fractionation produced from automated processing of whole blood or for the manufacture of other blood products not specified in Table 8.5. Sections "8.4 Evaluation of new fresh frozen plasma/cryoprecipitate components for transfusion" and "8.6 Generic protocol for the evaluation of apheresis equipment" should also be consulted if the collection device is new and/or intended for multiple purposes e.g. plasma for fractionation and clinical plasma (FFP). Where appropriate, methods must be those recommended by the European pharmacopeia or a validated equivalent method, for example total protein.
Before freezing:
*Particularly relevant to plasma which has been collected by any filtration technique. If filtration is done outside the collection procedure, assays should be performed before and after filtration.
During storage:
Table 8.5 Evaluation of novel plasma for the manufacture of immunoglobulin
Table 8.5 gives a summary of which assays are recommended for the manufacture of immunoglobulins only. Advice may be sought from SACBC on the validation requirements for plasma for the manufacture of labile proteins such as clotting factors.
Assessment 1,2 | Whole blood derived | Apheresis derived | Novel filter |
---|---|---|---|
Volume3 | |||
Leucocyte content3 | |||
Platelets3 | |||
Red cells3 | |||
Plasma Haemoglobin4 | ? | ? | ? |
Total protein | |||
Albumin | |||
IgG | |||
Markers of unwanted activation of coagulation5e.g. TAT, Frag1.2, FPA, FXIIa, FVIIa, FXIa, C1 inhibitor, S2302 | |||
PT ratio, APTT ratio6 | ? | ? | ? |
FVII, FVIII, Fibrinogen6 | ? | ? | ? |
Complement C3a, C5a4 | ? | ? | ? |
1Where appropriate, methods must be those recommended by the European pharmacopeia or a validated equivalent method
2Additional assays may need to be performed to comply with requirements from fractionators
3Tests are only required prior to freezing
4Parameter may be required by fractionators – needs to be confirmed. If required parameter will become mandatory
5Included due to reports of batches of immunoglobulins ‘contaminated’ with FXIa, resulting in thrombotic events
6Recommended to future proof against the use of plasma for the manufacture of labile proteins such as clotting factors